Baikal-GVD Document 24-v1

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

[ICRC 2021] Monitoring of optical properties of deep lake water

Document #:
Baikal-GVD-doc-24-v1
Document type:
Paper
Submitted by:
Yury Malyshkin
Updated by:
Yury Malyshkin
Document Created:
11 Oct 2022, 18:28
Contents Revised:
11 Oct 2022, 18:28
Metadata Revised:
12 Nov 2022, 15:59
Viewable by:
  • Public document
Modifiable by:

Quick Links:
Latest Version

Abstract:
We present the results of the one year monitoring of absorption and scattering lengths of light with wavelength 375–532 nm within the effective volume of the deep underwater neutrino telescope Baikal-GVD, which were measured by a device «BAIKAL-5D». The «BAIKAL-5D» was installed during the 2020 winter expedition at a depth of 1250 m. To carry out the optical measurements, we use a device with a shaded point-like isotropic light source having a spectral resolution of about 3 nm. A wide angle light receiver is moved by a stepper motor so that the distance between the receiver and the light source can vary from 0.9 m to 7.4 m. The absorption and scattering lengths were measured every week in 6 spectral points. The short-time variation of absorption length was estimated.
Files in Document:
Topics:
Publication Information:
https://doi.org/10.22323/1.395.1034
DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

DocDB Version 8.8.12, contact Document Database Administrators